Search
Search
Confirm
Cancel
>
>
>
TL一(yī)BLDC24-120C
ververvre
ververvre

TL一(yī)BLDC24-120C

The controller is a brushless roller controller with soft start function, forward/reverse rotation, VR speed regulation, overcurrent and locked rotor, short circuit, overvoltage and undervoltage, overtemperature and other functions.
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Category: Drive card
Quantity
-
+
Stock:
0
1
Detailed

Controller technical parameters

Top item

technical parameter

Top item

technical parameter

Rated voltage

twenty four

V

Voltage protection parameters

Rated current

5

A

Overvoltage protection value

28 ± 1

V

Stepless speed regulation

Have

 

Overvoltage protection delay

50 ± 10

MS

Gear speed regulation

None (X file)

 

Speed ​​closed loop

None ± 1 00

RPM

Forward/reverse control

Have

 

Standby start protection value

17 ± 0.5

V

Soft start time

<1000

MS

Undervoltage protection delay

1000 ± 100

MS

Braking time

<150

MS

Restore voltage value when under voltage

18 ± 0.5

V

Communication function

without

 

Voltage recovery delay when under voltage

50 ± 10

MS

Overload protection parameters

Overload protection current 1

1 0 ± 3

 

Overload protection delay 1

5000 ± 500

MS

Overload protection current 2

12 ± 3

 

Overload protection delay 2

2000 ± 200

MS

Overload protection current 3

1 5 ± 3

 

Overload protection delay 3

100 ± 20

MS

Overload protection current 4

1 8 ± 3

 

Overload protection delay 4

30 ± 1 0

MS

Current limit protection value

20 ± 3

 

Locked-rotor protection delay

100 ± 1 0

MS

Short circuit protection value

> 150

 

 

 

 

Motor low-speed running protection parameters (the following 3 tops need to be established at the same time)

Overspeed value

<120

RPM

Current value

> 1 0

A

Delay time

500 ± 50

MS

 

 

 

MOS tube temperature parameters (B3435)

Over temperature protection value

83 ± 5

120 ℃

Over temperature protection delay time

500 ± 30

 

Over temperature protection recovery value

80 ± 5

35 ℃

Over temperature protection recovery delay time

500 ± 1 0

 

Battery pack temperature parameter <B3950)

Over temperature protection value

 

120 ℃

Over temperature protection delay time

500 ± 30

U)

Over temperature protection recovery value

 

35 ℃

Over temperature protection recovery delay time

500 ± 1 0

CD

Electrical Specifications

Working temperature

One 20, 50 ℃

Key components

NCE4080K TO一(yī)252

 

Fault prompt (please refer to the following for products with indicator function)

 

Fault description

Indicating status

illustrate

Fault description

Indicating status

illustrate

Over/under voltage fault

LED flashes slowly 2 times

Bright 500MS2 times fire for 1.5 seconds

Level 1 overcurrent fault

LED flashes once

旯200MS1 fire for 1 second

Startup failure

LED flashes slowly 3 times

On for 500MS3 times, off for 1.5 seconds

Level 2 overcurrent fault

LED flashes 2 times

On for 200MS, 2 times, off for 1 second

 

LED flashes slowly 4 times

500MS 4 times for 1.5 seconds

Level 3 overcurrent fault

LED flashes 3 times

旯200MS3 fires for 1 second

MOS tube NTC open/short circuit fault

LED flashes slowly 5 times

On for 500 MS5 times, off for 1.5 seconds

Level 4 overcurrent fault

LED flashes 4 times

On for 200MS, 4 times, off for 1 second

MOS tube NTC over temperature fault

LED flashes slowly 6 times

On for 500MS6 times, off for 1.5 seconds

Short circuit

LED flashes 5 times quickly

On for 200MS, 5 times, off for 1 second

Battery pack NTC open/short circuit fault

LED flashes slowly 7 times

Bright 500MS7 times for 1.5 seconds

Stall failure

LED flashes 6 times

Bright 200MS6 fires for 1 second

Battery pack N D C over temperature fault

LED flashes slowly 8 times

On for 500MS8 times, off for 1.5 seconds

Low speed operation failure

LED flashes 7 times

On for 200MS, 7 times, off for 1 second

Products with communication indicate failures as follows

Report communication failure 1

without

Bright 200MS, 1 fire for 2.6 seconds

 

 

 

 

without

200MS on for 2 times, off for 2.6 seconds

 

 

 

Battery pack overvoltage

without

Illuminate 200MS 3 times and fire for 2.6 seconds

 

 

 

Battery pack is overheated

without

%200MS 4 fires for 2.6 seconds

 

 

 

 

without

%200MS 5 times off for 2.6 seconds

 

 

 

Instructions

1. Connect power to the controller, press the forward or reverse switch, the motor starts, release the switch, the motor immediately stops and brakes, braking time <: 150MS through VR to adjust the running speed, the speed control range: 180RPM, 3600RPM

2. LED indication: none

3. Communication function: none

4. Factory parameter setting:

Long press the set button for 0.5 seconds to enter the motor pole pair setting, the display shows the current pole pair number, short press the set button to adjust the speed of the pole pair number 6 one to 5 one 4 to set the phase according to the actual motor pole pair parameters After setting the matched value, press and hold for 0,5 seconds to confirm and exit the setting.

 

Download: Keyboard instruction manual_V1.0.PDF

Download: TLRVC21-200L-R manual_V1.0.PDF

MORE PRODUCTS

Messages

 

If you have any good suggestions and comments on our company, or want to consult our products, please fill in the form below, and we will contact you at the first time!

Username used for comment:
客戶留言
Description:
微信公衆号
Wechat
微信公衆号
Tiktok
© 2021 Dongguan Tonlo Machinery Technology Co., Ltd Powered by 300.cn